Quantcast
Channel: Disk Enclosures topics
Viewing all articles
Browse latest Browse all 773

776 (Ready for Recovery) and 785 (Parity initial. in progress) on two logical drives

$
0
0

Hi,

 

We have : Smart Array P600 Controller

 

In RAID 5 configuration, one disk had malfunction - ADU predicted that disk will fail, so we replaced that disk.

 

Rebuld was started ok, and reached 90%, but after that when we returned to ACU we have two errors:

 

776

(Ready for Recovery) Logical Drive 3 (2.0 TB, RAID 5) is queued for rebuilding.

 

785

Background parity initialization is currently queued or in progress on Logical Drive 2 (5.0 GB, RAID 5). If background parity initialization is queued, it will start when I/O is performed on the drive. When background parity initialization completes, the performance of the logical drive will improve.

 

 

Situations with drives are:

 

 

Logical drive 3 (2 TB, RAID 5):

Status

Ready for Rebuild

Rebuild Percentage Complete

0%

Drive Number

3

Drive Unique ID

600508B1001038373320202020200008

Size

2097151 MB

Fault Tolerance

RAID 5

Heads

255

Sectors/Track

32

Cylinders

65535

Strip Size

64 KB

Full Stripe Size

320 KB

Array Accelerator

Enabled

Parity Initialization Status

Initialization Completed

Disk Name

\\.\PhysicalDrive2

 

 

 

Logical drive 2 (5 GB, RAID 5)

 

 

Status

OK

Drive Number

2

Drive Unique ID

600508B1001038373320202020200007

Size

5119 MB

Fault Tolerance

RAID 5

Heads

255

Sectors/Track

32

Cylinders

1285

Strip Size

64 KB

Full Stripe Size

320 KB

Array Accelerator

Enabled

Parity Initialization Status

In Progress

Disk Name

\\.\PhysicalDrive1

Disk Partition Information

Partition Number: 1, Size: 5.0 GB, Mount Point: Unknown

 

In ADU log – there is no information about aborted buidling, but only   I see „read error“

 

 

Logical Drive 3:

     Drive Status:           Ready for recovery

     Blocks to Rebuild:     0

     Blocks Re-mapped:      

     Spare Status Flags:     0x00

     Spare to Replaced Map: See Big Spare to Replace Map:

     Media Was Exchanged:   No

     Cache Failure:         No

     Expand Failure:         0x00

     Unit Flags:             0x01 (Read Error)

     Big Remap Count:       Bus ID Count ID Count ID Count ID Count ID Count

                             1     2 002fh

     Big Drive Failure Map:     0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000

     Big Replacement Drive Map: 0x0008 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000

     Big Active Spare Map:     0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000

     Big Spare to Replace Map: No spares have replaced any drives

     Big Spare Marked OK Map:   0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000

 

 

 

 

I found information that restart may be help for rebuild to start, but Partiy initialization is in progress, so I don't what to do … To speed up initialization ? Or just wait ??

 

 

best regards and thak you for your time,

 

Indira