Hi,
We have : Smart Array P600 Controller
In RAID 5 configuration, one disk had malfunction - ADU predicted that disk will fail, so we replaced that disk.
Rebuld was started ok, and reached 90%, but after that when we returned to ACU we have two errors:
776
(Ready for Recovery) Logical Drive 3 (2.0 TB, RAID 5) is queued for rebuilding.
785
Background parity initialization is currently queued or in progress on Logical Drive 2 (5.0 GB, RAID 5). If background parity initialization is queued, it will start when I/O is performed on the drive. When background parity initialization completes, the performance of the logical drive will improve.
Situations with drives are:
Logical drive 3 (2 TB, RAID 5):
Status
Ready for Rebuild
Rebuild Percentage Complete
0%
Drive Number
3
Drive Unique ID
600508B1001038373320202020200008
Size
2097151 MB
Fault Tolerance
RAID 5
Heads
255
Sectors/Track
32
Cylinders
65535
Strip Size
64 KB
Full Stripe Size
320 KB
Array Accelerator
Enabled
Parity Initialization Status
Initialization Completed
Disk Name
\\.\PhysicalDrive2
Logical drive 2 (5 GB, RAID 5)
Status
OK
Drive Number
2
Drive Unique ID
600508B1001038373320202020200007
Size
5119 MB
Fault Tolerance
RAID 5
Heads
255
Sectors/Track
32
Cylinders
1285
Strip Size
64 KB
Full Stripe Size
320 KB
Array Accelerator
Enabled
Parity Initialization Status
In Progress
Disk Name
\\.\PhysicalDrive1
Disk Partition Information
Partition Number: 1, Size: 5.0 GB, Mount Point: Unknown
In ADU log – there is no information about aborted buidling, but only I see „read error“
Logical Drive 3:
Drive Status: Ready for recovery
Blocks to Rebuild: 0
Blocks Re-mapped:
Spare Status Flags: 0x00
Spare to Replaced Map: See Big Spare to Replace Map:
Media Was Exchanged: No
Cache Failure: No
Expand Failure: 0x00
Unit Flags: 0x01 (Read Error)
Big Remap Count: Bus ID Count ID Count ID Count ID Count ID Count
1 2 002fh
Big Drive Failure Map: 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
Big Replacement Drive Map: 0x0008 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
Big Active Spare Map: 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
Big Spare to Replace Map: No spares have replaced any drives
Big Spare Marked OK Map: 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
I found information that restart may be help for rebuild to start, but Partiy initialization is in progress, so I don't what to do … To speed up initialization ? Or just wait ??
best regards and thak you for your time,
Indira