HP jointware Carepack u2e45e
Simple question, what is HPe refering to when they say Jointware. I have seen it popup all over the place in carepacks such as this one but no good deffition of how they define jointware. Thanks!
View ArticleP2000 G3 iSCSI
I have a failed drive that have been replaced.The current status of the drive is "AVAIL"I wanted to add it as a dedicated spare to my VDISK running RAID10If I do this will I loose the data on the VDISK?
View ArticleFailed Drive replacement not taking
Our db server has a logical raid 1 drive. One of the drives failed. I have tried four different replacement drives and they all fail. Its giving me a drive mix 0x25 error for the reason it failed. they...
View ArticleHP jointware Carepack u2e45e
Simple question, what is HPe refering to when they say Jointware. I have seen it popup all over the place in carepacks such as this one but no good deffition of how they define jointware. Thanks!
View ArticleSmart Array P410 firmware update from 3.50 to 6.64?
I have been investigating a performance problem on a Windows SBS 2011 virtual server hosted on a Microsoft Windows Hyper-V 2012 R2 server host. The virtual machine and virtual hard drive files are...
View ArticleRAID 0 - NVMe Enterprise SSD in ProLiant Gen9
Upon first setup and install of our new server, the HPE storage management utility, did not recognize my 2 new disks, which i would like to setup in RAID 0 or 1.Using this ProLiant Gen 9 server and 2 x...
View ArticleProLiant BL460c Gen9 X64 Exception Type 02 - NMI Detected
After upgrading a ProLiant BL460c Gen9 to BIOS version 2.20 05/05/2016 we're receiving a screen of red text and unable to get into any system utilities.The server does not go so far as to boot from any...
View ArticleDC power supplies for a D2700?
I can't find a reference to anything that says these exist. I see that the D2700 takes a "common slot" PSU, and there's a DC chassis for a P2000 (to which the DC D2700 attaches), but there isn't a VDC...
View ArticleHP jointware Carepack u2e45e
Simple question, what is HPe refering to when they say Jointware. I have seen it popup all over the place in carepacks such as this one but no good deffition of how they define jointware. Thanks!
View ArticleSmart Array P410 firmware update from 3.50 to 6.64?
I have been investigating a performance problem on a Windows SBS 2011 virtual server hosted on a Microsoft Windows Hyper-V 2012 R2 server host. The virtual machine and virtual hard drive files are...
View ArticleD2700 Array has ALL amber lights on drives, ALL green everywhere else.
I have an HP D2700 disk enclosure with twelve (12) HP 3TB SAS HHDs installed, configured in RAID 6 as a single 30TB volume formatted XFS.The array has been working fine but has not been used very much...
View ArticleD2700 and P411 controller
I seem to have several threads on this issue, but I have yet to get an answer. I have one d2700 direct connected via SAS to a P411 controller inside a DL580 G8.. ORCA sees and attempts initialize the...
View ArticleStorage arrays P2000 and MSA 2040 - Getting disk drive model using telnet / CLI.
Hey all,Is it possible to get disk drive model using CLI ? I've spent some time on it today and I am affraid that an answer will be that no.show disks command is getting me serial number, but not...
View ArticleHP PROLIANT DL 380 G7 RAID 5
Hi,I want to know if i can add a new disk on a working server configure in RAID 5 and then make this new disk as a spare disk. Because i don't have spare disk configure on my server but it's working...
View Articleproblem with firmware update on msa2212fc controller
Hi!we have HP MSA2000 G2 AJ949A) that was running with 8 disks on one msa2212fc controller for last couple of month.s. Lat night we have updated controller with latest firmware (202P01 (A) and now...
View Articlep410i support SSD
HI everyone, did somebody test SSD intel pro 2500 or Samsung pro 850 on p410i, i want to know which speed i can get on RAID 10 or 50? Or what advice can you give for this controller in low price range,...
View ArticleSmart Array P410i warning "Dirty Cache Line Unable To Flush To Drives"
I get the output of:hpacucli.exe ctrl all show config detailemailed to me each day.It now includes this line in the Smart Array P410i in Slot 0 (Embedded) sectionCache Status Details: A cache error was...
View Article[P410i] - Array is ready for recovery, but never rebuilds
One of my disks in a 2-drive RAID1 array died.So I replaced the disk. Now the array says, ready for recovery, but never recovers.Attached you will find the report from the controller.I uploaded a copy...
View ArticleStorageWorks D2700 ACU can't see physical drives
hello, I have the same enclosure, although, I am unable to get the ACU to see the physical drives, it sees the controllers, but thats it.How did you get it configured? Upon install, did you simply run...
View ArticleD2700 Firmware Update to 0150 Temparature Sensor Overheated
Hello,I have updated to Windows Server 2016 and use the new HP Proliant SPP to update my Firmware. This has Updated my D2700 with the new Firmware 0150. after this i have a error on it. it says the...
View Article